Asia Events
|
|
|
|
|
|
Blue-White Industries |
|
|
|
|
|
|
|
 |
Myron L - CONTROLSTIK II™ - Rinse Tank System |
|
Myron L - CONTROLSTIK II™ - Rinse Tank System
The Myron L CONTROLSTIK II Rinse Tank System dramatically reduces the amount of water used in continuous flow rinse tanks. At the same time, it automatically maintains optimum water purity, ensuring effective rinsing.
Applications
- Continuous-flow rinse tanks
- Circuit board manufacturing
- Electroplating
- Wastewater
|
| |
| More Information |
| |
|
|
|
 |
|
 |
AIRE-O2® Aspirator Aerator |
|
AIRE-O2® Aspirator Aerator: The Industry Workhorse Since 1974
- Superior horizontal mixing
- High oxygen transfer
- Easy installation
- Dependable, extended service life
- Low maintenance
- Highly energy-efficient
- Superior winter performance
- No aerosols
- Simplifies retrofits and upgrades
|
| |
| More Information |
| |
|
|
|
 |
|
 |
Hydranautics - SWC (seawater composite) membranes |
|
The first choice in seawater desalination
Hydranautics has over two decades of experience in desalination and over 1.27 million cubic meters (337 MGD) per day of seawater treated by their SWC (seawater composite) membranes. With more installed capacity than any other competitor, the SWC membrane provides unparalleled and consistent operating performance. |
| |
| More Information |
| |
|
|
|
 |
|
 |
Smith & Loveless Inc - FAST® Fixed Activated Sludge Treatment |
|
Stabilizing Your Variable Flows
Proven. Reliable. Simple. That's what characterizes the patented Fixed Activated Sludge Treatment [FAST®] Process by Smith & Loveless.
- Proven in thousands of installations ranging from municipal and private development [on-site] applications to industrial and commercial sectors to specialized use in marine systems.
- Reliable because its stable process withstands hydraulic shock loads and prevents bacterial washouts.
- Simple operation & maintenance means no daily operator requirements and very little annual plant maintenance.
|
| |
| More Information |
| |
|
|
|
 |
|
 |
Chemical Injection Technologies - SUPERIOR Gas Chlorinator - CL Series |
|
SUPERIOR Gas Chlorinator - Series CL-1
100 PPD (2000 Gr/Hr) Direct Cylinder Mounted - All Vacuum
The SUPERIORTM Series CL-1 Gas Chlorinator is a state-of-the-art, vacuum-operated, solution feed type which mounts directly on a chlorine cylinder valve. The chlorinator is mounted onto the chlorine cylinder valve using a very heavy-duty, positive yoke clamp connection. A chlorine gas flow meter panel indicates the amount of chlorine being fed and may be located wherever it Is safest and most convenient. Chlorine flow rate is manually adjusted and the design permits easy addition of a number of automatic flow rate control devices. A high efficiency, water operated ejector produces the vacuum necessary to operate the system. The ejector assembly contains a back-flow check valve system to prevent pressurized water from entering the chlorinator. A spring-opposed diaphragm vacuum regulator controls the chlorine gas flow rate and also acts as the safety shut-off valve. |
| |
| More Information |
| |
|
|
|
 |
|
 |
GA Industries Inc - AWWA Ball Valves Resilient Seated |
|
The Golden Anderson Rotary Valve is a fully ported valve which employs several unique design features that make the Rotary Valve the most dependable and easy to maintain type valve available today!
These features include:
- Hydraulically actuated seating to ensure tight shut-off while minimizing seat wear.
- One piece body casting with integrally cast flanges eliminates seat and rotor alignment problems.
- Separate top cover and seat access cover for ease of maintenance and rotor seat replacement.
- Microdrive operating mechanism provides excellent shut-off characteristics.
|
| |
| More Information |
| |
|
|
|
 |
|
 |
Pipeline Services - PIPE CLEANING |
|
High Pressure Water Jetting
Pipeline Services offer a choice of pipe cleaning systems suitable for all types of pipes, drains and conduits. Some of the factors in determining the most suitable equipment for the job include....
- Pipe material.
- Pipe diameter.
- Pipe shape.
- Access points along with location and suitability for vehices.
- Reasons for Jetting such as silt, scale, roots protective coatings
|
| |
| More Information |
| |
|
|
|
 |
|
 |
Wallingford Software - InfoNet |
|
 Asset and data management system for water networks - water supply, water distribution, wastewater collection, sewers and storm water
With InfoNet you can:
- Store, validate, review, clean, edit and analyse all water infrastructure asset data in a single database
- Improve both planning and operational decision-making
- Increase the value and use of spatial and asset data
- Utilise the same user interface as InfoWorks for immediate high productivity
- Exploit the benefits immediately through using commercial off-the-shelf solutions
|
| |
| More Information |
| |
|
|
|
 |
|
 |
Sereco - PRTP - Peripheral drive scraper for circular clarifier |
|
The peripheral drive scraper for circular clarifier type PRTP consists of a mobile girder used as a walkway, a slewing ring unit, a central deflector, a traction trolley, a drive unit, a scum box, a skimming blade, a set of sludge scraper blades, a peripheral deflector and a weir.
Strengths:
- Mobile girder with a length equal to the radius or, on request, to 1 + 1/3 of the clarifier radius.
- Sludge extraction system of scraping type.
- Highsturdinessofthe rotating bridge.
- Minimum energy consumption.
- Contemporaneous elimination of settled sludge and floating materials.
|
| |
| More Information |
| |
|
|
|
 |
|
 |
Severn Trent - Chlorine Dioxide Generation Systems |
|
Severn Trent - Chlorine Dioxide Generation Systems
Severn Trent Services offers the Capital Controls™ Model T70G4000 and T70GD4000 chlorine dioxide generators to produce the disinfectant chemical using reagents in either commercially available or diluted concentrations. Both systems produce chlorine dioxide and consistently maintain a product yield greater than 95%, making it ideal for drinking water treatment. As all-liquid systems, the Capital Controls chlorine dioxide generators assure efficient gas production, precise solution feeding, low maintenance and dependable operation for the life of the equipment. Both models are available with either manual or automatic control in addition to system shut-down and alarm options. |
| |
| More Information |
| |
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
| Winston Engineering - Pump Specialist |
|
| Wallingford Software |
|
|
|
|